Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth72mm
Release characteristicC
Voltage typeAC
Frequency50 - 60Hz
Power loss10.8W
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Number of poles (total)4
Number of protected poles4
Rated voltage400V
Rated current25A
Rated impulse withstand voltage Uimp6kV
Rated insulation voltage Ui500V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V30kA
Flush-mounted installationNo
Width in number of modular spacings6
Over voltage category4
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 60°C
Pollution degree2
Connectable conductor cross section multi-wired50 - 50mm²
Additional equipment possibleYes
Connectable conductor cross section solid-core70 - 70mm²
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW93242 | High Perf. MCB 4P C25 25KA 6M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth

72mm

Release characteristic

C

Voltage type

AC

Frequency

50 .. 60Hz

Power loss

10.8W

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Number of poles (total)

4

Number of protected poles

4

Rated voltage

400V

Rated current

25A

Rated impulse withstand voltage Uimp

6kV

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

30kA

Flush-mounted installation

Width in number of modular spacings

6

Over voltage category

4

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 60°C

Pollution degree

2

Connectable conductor cross section multi-wired

50 .. 50mm²

Additional equipment possible

Connectable conductor cross section solid-core

70 .. 70mm²

Explosion-proof

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.