Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated voltage230V
Voltage typeAC
Rated insulation voltage Ui500V
Rated current4.12A
Built-in depth72mm
Release characteristicC
Number of protected poles2
Leakage current typeOther
Connectable conductor cross section multi-wired35 - 35mm²
Connectable conductor cross section solid-core35 - 35mm²
Current limiting class1
Surge current capacity3kA
Pollution degree2
Rated short-circuit breaking capacity according to IEC 60947-26kA
With interlocking deviceNo
Over voltage category3
Number of poles (total)2
Concurrently switching neutral conductorNo
Power loss10W
Ambient temperature during operating-25 - 40°C
Flush-mounted installationNo
Anti-nuisance tripping versionYes
Frequency50/60 Hz
Degree of protection (IP)IP20
Width in number of modular spacings2
Disconnection characteristicShort-time delayed
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity according to EN 610096kA
Rated fault current0.03A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95936

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated voltage

230V

Voltage type

AC

Rated insulation voltage Ui

500V

Rated current

4.12A

Built-in depth

72mm

Release characteristic

C

Number of protected poles

2

Leakage current type

Other

Connectable conductor cross section multi-wired

35 .. 35mm²

Connectable conductor cross section solid-core

35 .. 35mm²

Current limiting class

1

Surge current capacity

3kA

Pollution degree

2

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

With interlocking device

Over voltage category

3

Number of poles (total)

2

Concurrently switching neutral conductor

Power loss

10W

Ambient temperature during operating

-25 .. 40°C

Flush-mounted installation

Anti-nuisance tripping version

Frequency

50/60 Hz

Degree of protection (IP)

IP20

Width in number of modular spacings

2

Disconnection characteristic

Short-time delayed

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity according to EN 61009

6kA

Rated fault current

0.03A

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.