Technical specifications

Rated insulation voltage Ui500V
Rated impulse withstand voltage Uimp4kV
Number of poles (total)2
Number of protected poles2
Rated voltage230V
Rated current10A
Rated fault current0.03A
Leakage current typeOther
Voltage typeAC
Disconnection characteristicShort-time delayed
Surge current capacity3kA
Power loss10W
With interlocking deviceNo
Rated short-circuit breaking capacity according to IEC 60947-26kA
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Frequency50/60 Hz
Over voltage category3
Pollution degree2
Rated short-circuit breaking capacity according to EN 610096kA
Concurrently switching neutral conductorNo
Release characteristicC
Current limiting class1
Ambient temperature during operating-25 - 40°C
Flush-mounted installationNo
Width in number of modular spacings2
Anti-nuisance tripping versionYes
Built-in depth72mm
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired35 - 35mm²
Connectable conductor cross section solid-core35 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95936 | Compact RCBO 2P C10 6KA F/0,03 2M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

4kV

Number of poles (total)

2

Number of protected poles

2

Rated voltage

230V

Rated current

10A

Rated fault current

0.03A

Leakage current type

Other

Voltage type

AC

Disconnection characteristic

Short-time delayed

Surge current capacity

3kA

Power loss

10W

With interlocking device

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Frequency

50/60 Hz

Over voltage category

3

Pollution degree

2

Rated short-circuit breaking capacity according to EN 61009

6kA

Concurrently switching neutral conductor

Release characteristic

C

Current limiting class

1

Ambient temperature during operating

-25 .. 40°C

Flush-mounted installation

Width in number of modular spacings

2

Anti-nuisance tripping version

Built-in depth

72mm

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

35 .. 35mm²

Connectable conductor cross section solid-core

35 .. 35mm²