Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated insulation voltage Ui500V
Rated impulse withstand voltage Uimp4kV
Number of protected poles2
Rated voltage230V
Voltage typeAC
Disconnection characteristicShort-time delayed
Surge current capacity3kA
Power loss10W
With interlocking deviceNo
Rated short-circuit breaking capacity according to IEC 60947-26kA
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Frequency50/60 Hz
Over voltage category3
Pollution degree2
Rated short-circuit breaking capacity according to EN 610096kA
Concurrently switching neutral conductorNo
Release characteristicC
Current limiting class1
Ambient temperature during operating-25 - 40°C
Flush-mounted installationNo
Width in number of modular spacings2
Anti-nuisance tripping versionYes
Built-in depth72mm
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired35 - 35mm²
Connectable conductor cross section solid-core35 - 35mm²
Rated current10A
Rated fault current0.03A
Leakage current typeOther
Number of poles (total)2
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95936 | Compact RCBO 2P C10 6KA F/0,03 2M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

4kV

Number of protected poles

2

Rated voltage

230V

Voltage type

AC

Disconnection characteristic

Short-time delayed

Surge current capacity

3kA

Power loss

10W

With interlocking device

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Frequency

50/60 Hz

Over voltage category

3

Pollution degree

2

Rated short-circuit breaking capacity according to EN 61009

6kA

Concurrently switching neutral conductor

Release characteristic

C

Current limiting class

1

Ambient temperature during operating

-25 .. 40°C

Flush-mounted installation

Width in number of modular spacings

2

Anti-nuisance tripping version

Built-in depth

72mm

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

35 .. 35mm²

Connectable conductor cross section solid-core

35 .. 35mm²

Rated current

10A

Rated fault current

0.03A

Leakage current type

Other

Number of poles (total)

2

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.