Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Leakage current typeOther
Power loss16W
Frequency50/60 Hz
Rated voltage230V
Surge current capacity3kA
Concurrently switching neutral conductorNo
Degree of protection (IP)IP20
Rated current4.56A
Rated insulation voltage Ui500V
Over voltage category3
Rated fault current0.03A
Release characteristicC
Built-in depth72mm
Width in number of modular spacings2
Voltage typeAC
Rated short-circuit breaking capacity according to IEC 60947-26kA
Number of protected poles2
Pollution degree2
Number of poles (total)2
With interlocking deviceNo
Connectable conductor cross section multi-wired35 - 35mm²
Connectable conductor cross section solid-core35 - 35mm²
Flush-mounted installationNo
Current limiting class1
Ambient temperature during operating-25 - 40°C
Anti-nuisance tripping versionYes
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Rated short-circuit breaking capacity according to EN 610096kA
Rated impulse withstand voltage Uimp4kV
Disconnection characteristicShort-time delayed
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95937

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Leakage current type

Other

Power loss

16W

Frequency

50/60 Hz

Rated voltage

230V

Surge current capacity

3kA

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Rated current

4.56A

Rated insulation voltage Ui

500V

Over voltage category

3

Rated fault current

0.03A

Release characteristic

C

Built-in depth

72mm

Width in number of modular spacings

2

Voltage type

AC

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Number of protected poles

2

Pollution degree

2

Number of poles (total)

2

With interlocking device

Connectable conductor cross section multi-wired

35 .. 35mm²

Connectable conductor cross section solid-core

35 .. 35mm²

Flush-mounted installation

Current limiting class

1

Ambient temperature during operating

-25 .. 40°C

Anti-nuisance tripping version

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Rated short-circuit breaking capacity according to EN 61009

6kA

Rated impulse withstand voltage Uimp

4kV

Disconnection characteristic

Short-time delayed

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.