Number of poles (total)2
Rated fault current0.03A
Number of protected poles2
Rated voltage230V
Rated impulse withstand voltage Uimp4kV
Rated insulation voltage Ui500V
Leakage current typeOther
Current limiting class1
Rated short-circuit breaking capacity according to IEC 60947-26kA
Rated current16A
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Power loss16W
Rated short-circuit breaking capacity according to EN 610096kA
Disconnection characteristicShort-time delayed
With interlocking deviceNo
Voltage typeAC
Surge current capacity3kA
Release characteristicC
Concurrently switching neutral conductorNo
Frequency50/60 Hz
Width in number of modular spacings2
Ambient temperature during operating-25 - 40°C
Pollution degree2
Over voltage category3
Flush-mounted installationNo
Built-in depth72mm
Anti-nuisance tripping versionYes
Connectable conductor cross section multi-wired35 - 35mm²
Degree of protection (IP)IP20
Connectable conductor cross section solid-core35 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95937 | Compact RCBO 2P C16 6KA F/0,03 2M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)

2

Rated fault current

0.03A

Number of protected poles

2

Rated voltage

230V

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

500V

Leakage current type

Other

Current limiting class

1

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Rated current

16A

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Power loss

16W

Rated short-circuit breaking capacity according to EN 61009

6kA

Disconnection characteristic

Short-time delayed

With interlocking device

Voltage type

AC

Surge current capacity

3kA

Release characteristic

C

Concurrently switching neutral conductor

Frequency

50/60 Hz

Width in number of modular spacings

2

Ambient temperature during operating

-25 .. 40°C

Pollution degree

2

Over voltage category

3

Flush-mounted installation

Built-in depth

72mm

Anti-nuisance tripping version

Connectable conductor cross section multi-wired

35 .. 35mm²

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

35 .. 35mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.