Frequency50/60 Hz
Built-in depth72mm
Voltage typeAC
Degree of protection (IP)IP20
Rated fault current0.03A
Width in number of modular spacings2
Release characteristicC
Leakage current typeOther
Surge current capacity3kA
Power loss13W
Pollution degree2
Rated insulation voltage Ui500V
Rated voltage230V
Rated current13A
Over voltage category3
Current limiting class1
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity according to IEC 60947-26kA
Number of protected poles2
Ambient temperature during operating-25 - 40°C
Rated short-circuit breaking capacity according to EN 610096kA
Connectable conductor cross section solid-core35 - 35mm²
Rated impulse withstand voltage Uimp4kV
Disconnection characteristicShort-time delayed
Anti-nuisance tripping versionYes
With interlocking deviceNo
Number of poles (total)2
Flush-mounted installationNo
Connectable conductor cross section multi-wired35 - 35mm²
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95941

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Frequency

50/60 Hz

Built-in depth

72mm

Voltage type

AC

Degree of protection (IP)

IP20

Rated fault current

0.03A

Width in number of modular spacings

2

Release characteristic

C

Leakage current type

Other

Surge current capacity

3kA

Power loss

13W

Pollution degree

2

Rated insulation voltage Ui

500V

Rated voltage

230V

Rated current

13A

Over voltage category

3

Current limiting class

1

Concurrently switching neutral conductor

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Number of protected poles

2

Ambient temperature during operating

-25 .. 40°C

Rated short-circuit breaking capacity according to EN 61009

6kA

Connectable conductor cross section solid-core

35 .. 35mm²

Rated impulse withstand voltage Uimp

4kV

Disconnection characteristic

Short-time delayed

Anti-nuisance tripping version

With interlocking device

Number of poles (total)

2

Flush-mounted installation

Connectable conductor cross section multi-wired

35 .. 35mm²

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA