Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Voltage typeAC
Built-in depth72mm
Frequency50/60 Hz
Rated short-circuit breaking capacity according to IEC 60947-210kA
Width in number of modular spacings2
Rated voltage400V
Release characteristicB
Degree of protection (IP)IP20
Pollution degree2
Concurrently switching neutral conductorNo
Rated current4.56A
Current limiting class1
Rated insulation voltage Ui500V
Power loss16W
Rated fault current0.03A
Number of protected poles2
Surge current capacity3kA
Over voltage category3
Leakage current typeOther
Connectable conductor cross section solid-core35 - 35mm²
Connectable conductor cross section multi-wired35 - 35mm²
Anti-nuisance tripping versionYes
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Flush-mounted installationNo
Rated impulse withstand voltage Uimp4kV
Disconnection characteristicShort-time delayed
Rated short-circuit breaking capacity according to EN 6100910kA
Ambient temperature during operating-25 - 40°C
With interlocking deviceNo
Number of poles (total)2
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95967

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Voltage type

AC

Built-in depth

72mm

Frequency

50/60 Hz

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Width in number of modular spacings

2

Rated voltage

400V

Release characteristic

B

Degree of protection (IP)

IP20

Pollution degree

2

Concurrently switching neutral conductor

Rated current

4.56A

Current limiting class

1

Rated insulation voltage Ui

500V

Power loss

16W

Rated fault current

0.03A

Number of protected poles

2

Surge current capacity

3kA

Over voltage category

3

Leakage current type

Other

Connectable conductor cross section solid-core

35 .. 35mm²

Connectable conductor cross section multi-wired

35 .. 35mm²

Anti-nuisance tripping version

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Flush-mounted installation

Rated impulse withstand voltage Uimp

4kV

Disconnection characteristic

Short-time delayed

Rated short-circuit breaking capacity according to EN 61009

10kA

Ambient temperature during operating

-25 .. 40°C

With interlocking device

Number of poles (total)

2

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.