  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated voltage400V
Leakage current typeOther
Voltage typeAC
Rated fault current0.03A
Release characteristicB
Rated current5.44A
Rated insulation voltage Ui500V
Built-in depth72mm
Surge current capacity3kA
Current limiting class1
Ambient temperature during operating-25 - 40°C
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Pollution degree2
Rated short-circuit breaking capacity according to IEC 60947-210kA
Flush-mounted installationNo
Width in number of modular spacings2
Over voltage category3
Number of protected poles2
Rated short-circuit breaking capacity according to EN 6100910kA
Number of poles (total)2
Disconnection characteristicShort-time delayed
Rated impulse withstand voltage Uimp4kV
Anti-nuisance tripping versionYes
Frequency50/60 Hz
Connectable conductor cross section solid-core35 - 35mm²
Concurrently switching neutral conductorNo
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired35 - 35mm²
With interlocking deviceNo
Power loss20W
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95968

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated voltage

400V

Leakage current type

Other

Voltage type

AC

Rated fault current

0.03A

Release characteristic

B

Rated current

5.44A

Rated insulation voltage Ui

500V

Built-in depth

72mm

Surge current capacity

3kA

Current limiting class

1

Ambient temperature during operating

-25 .. 40°C

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Pollution degree

2

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Flush-mounted installation

Width in number of modular spacings

2

Over voltage category

3

Number of protected poles

2

Rated short-circuit breaking capacity according to EN 61009

10kA

Number of poles (total)

2

Disconnection characteristic

Short-time delayed

Rated impulse withstand voltage Uimp

4kV

Anti-nuisance tripping version

Frequency

50/60 Hz

Connectable conductor cross section solid-core

35 .. 35mm²

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

35 .. 35mm²

With interlocking device

Power loss

20W