Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Release characteristicB
Built-in depth72mm
Voltage typeAC
Rated insulation voltage Ui500V
Rated voltage400V
Rated current5.76A
Rated fault current0.03A
Surge current capacity3kA
Pollution degree2
Current limiting class1
Leakage current typeOther
Width in number of modular spacings2
Over voltage category3
Flush-mounted installationNo
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired35 - 35mm²
Anti-nuisance tripping versionYes
Number of protected poles2
Disconnection characteristicShort-time delayed
Concurrently switching neutral conductorNo
With interlocking deviceNo
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Frequency50/60 Hz
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity according to IEC 60947-210kA
Number of poles (total)2
Power loss25W
Ambient temperature during operating-25 - 40°C
Connectable conductor cross section solid-core35 - 35mm²
Rated short-circuit breaking capacity according to EN 6100910kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95969

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Release characteristic

B

Built-in depth

72mm

Voltage type

AC

Rated insulation voltage Ui

500V

Rated voltage

400V

Rated current

5.76A

Rated fault current

0.03A

Surge current capacity

3kA

Pollution degree

2

Current limiting class

1

Leakage current type

Other

Width in number of modular spacings

2

Over voltage category

3

Flush-mounted installation

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

35 .. 35mm²

Anti-nuisance tripping version

Number of protected poles

2

Disconnection characteristic

Short-time delayed

Concurrently switching neutral conductor

With interlocking device

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Frequency

50/60 Hz

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Number of poles (total)

2

Power loss

25W

Ambient temperature during operating

-25 .. 40°C

Connectable conductor cross section solid-core

35 .. 35mm²

Rated short-circuit breaking capacity according to EN 61009

10kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.