Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of protected poles2
Number of poles (total)2
Rated insulation voltage Ui500V
Rated impulse withstand voltage Uimp4kV
Power loss10W
Current limiting class3
Rated fault current0.3A
Rated current10A
Rated short-circuit breaking capacity according to EN 610096kA
Leakage current typeOther
Rated voltage230V
Rated short-circuit breaking capacity according to IEC 60947-210kA
Disconnection characteristicShort-time delayed
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Frequency50/60 Hz
Over voltage category3
Ambient temperature during operating-25 - 40°C
Concurrently switching neutral conductorNo
Pollution degree2
Width in number of modular spacings2
Anti-nuisance tripping versionYes
With interlocking deviceNo
Voltage typeAC
Release characteristicB
Flush-mounted installationNo
Built-in depth72mm
Connectable conductor cross section solid-core35 - 35mm²
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired35 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95976 | Compact RCBO 2P B10 6KA F/0,03 2M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of protected poles

2

Number of poles (total)

2

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

4kV

Power loss

10W

Current limiting class

3

Rated fault current

0.3A

Rated current

10A

Rated short-circuit breaking capacity according to EN 61009

6kA

Leakage current type

Other

Rated voltage

230V

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Disconnection characteristic

Short-time delayed

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Frequency

50/60 Hz

Over voltage category

3

Ambient temperature during operating

-25 .. 40°C

Concurrently switching neutral conductor

Pollution degree

2

Width in number of modular spacings

2

Anti-nuisance tripping version

With interlocking device

Voltage type

AC

Release characteristic

B

Flush-mounted installation

Built-in depth

72mm

Connectable conductor cross section solid-core

35 .. 35mm²

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

35 .. 35mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.