Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)2
Rated voltage230V
Rated insulation voltage Ui500V
Number of protected poles2
Rated fault current0.3A
Rated current16A
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity according to IEC 60947-210kA
Power loss16W
Leakage current typeOther
Current limiting class3
Rated short-circuit breaking capacity according to EN 610096kA
Disconnection characteristicShort-time delayed
Voltage typeAC
Concurrently switching neutral conductorNo
Release characteristicB
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
With interlocking deviceNo
Pollution degree2
Ambient temperature during operating-25 - 40°C
Frequency50/60 Hz
Built-in depth72mm
Degree of protection (IP)IP20
Over voltage category3
Width in number of modular spacings2
Flush-mounted installationNo
Connectable conductor cross section multi-wired35 - 35mm²
Anti-nuisance tripping versionYes
Connectable conductor cross section solid-core35 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW95977 | Compact RCBO 2P B16 6KA F/0,03 2M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)

2

Rated voltage

230V

Rated insulation voltage Ui

500V

Number of protected poles

2

Rated fault current

0.3A

Rated current

16A

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Power loss

16W

Leakage current type

Other

Current limiting class

3

Rated short-circuit breaking capacity according to EN 61009

6kA

Disconnection characteristic

Short-time delayed

Voltage type

AC

Concurrently switching neutral conductor

Release characteristic

B

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

With interlocking device

Pollution degree

2

Ambient temperature during operating

-25 .. 40°C

Frequency

50/60 Hz

Built-in depth

72mm

Degree of protection (IP)

IP20

Over voltage category

3

Width in number of modular spacings

2

Flush-mounted installation

Connectable conductor cross section multi-wired

35 .. 35mm²

Anti-nuisance tripping version

Connectable conductor cross section solid-core

35 .. 35mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.