Technical specifications

Number of poles (total)2
Number of protected poles1
Rated insulation voltage Ui500V
Rated current6A
Rated fault current0.3A
Rated impulse withstand voltage Uimp4kV
Leakage current typeAC
Rated voltage230V
Current limiting class3
Power loss6W
Rated short-circuit breaking capacity according to EN 610094.5kA
Rated short-circuit breaking capacity according to IEC 60947-26kA
Rated short-circuit breaking capacity Icn according to EN 61009-14.5kA
Disconnection characteristicUndelayed
Surge current capacity0.25kA
Over voltage category3
Built-in depth72mm
Flush-mounted installationNo
Pollution degree2
Width in number of modular spacings2
Ambient temperature during operating-25 - 40°C
Anti-nuisance tripping versionNo
Connectable conductor cross section solid-core35 - 35mm²
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired35 - 35mm²
Voltage typeAC
Frequency50/60 Hz
Release characteristicC
Concurrently switching neutral conductorYes
With interlocking deviceNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW94015 | Compact RCBO 1P+N C6 4.5KA AC/0.3 2M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)

2

Number of protected poles

1

Rated insulation voltage Ui

500V

Rated current

6A

Rated fault current

0.3A

Rated impulse withstand voltage Uimp

4kV

Leakage current type

AC

Rated voltage

230V

Current limiting class

3

Power loss

6W

Rated short-circuit breaking capacity according to EN 61009

4.5kA

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

4.5kA

Disconnection characteristic

Undelayed

Surge current capacity

0.25kA

Over voltage category

3

Built-in depth

72mm

Flush-mounted installation

Pollution degree

2

Width in number of modular spacings

2

Ambient temperature during operating

-25 .. 40°C

Anti-nuisance tripping version

Connectable conductor cross section solid-core

35 .. 35mm²

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

35 .. 35mm²

Voltage type

AC

Frequency

50/60 Hz

Release characteristic

C

Concurrently switching neutral conductor

With interlocking device