Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)2
Rated impulse withstand voltage Uimp4kV
Current limiting class3
Leakage current typeAC
Rated fault current0.3A
Power loss16W
Rated current16A
Number of protected poles1
Rated voltage230V
Rated insulation voltage Ui500V
Rated short-circuit breaking capacity Icn according to EN 61009-14.5kA
Rated short-circuit breaking capacity according to IEC 60947-26kA
Disconnection characteristicUndelayed
Frequency50/60 Hz
Surge current capacity0.25kA
Concurrently switching neutral conductorYes
Voltage typeAC
Release characteristicC
Anti-nuisance tripping versionNo
Built-in depth72mm
Over voltage category3
Rated short-circuit breaking capacity according to EN 610094.5kA
With interlocking deviceNo
Flush-mounted installationNo
Width in number of modular spacings2
Ambient temperature during operating-25 - 40°C
Connectable conductor cross section multi-wired35 - 35mm²
Degree of protection (IP)IP20
Pollution degree2
Connectable conductor cross section solid-core35 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW94017 | Compact RCBO 1P+N C16 4.5KA AC/0.3 2M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)

2

Rated impulse withstand voltage Uimp

4kV

Current limiting class

3

Leakage current type

AC

Rated fault current

0.3A

Power loss

16W

Rated current

16A

Number of protected poles

1

Rated voltage

230V

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity Icn according to EN 61009-1

4.5kA

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Disconnection characteristic

Undelayed

Frequency

50/60 Hz

Surge current capacity

0.25kA

Concurrently switching neutral conductor

Voltage type

AC

Release characteristic

C

Anti-nuisance tripping version

Built-in depth

72mm

Over voltage category

3

Rated short-circuit breaking capacity according to EN 61009

4.5kA

With interlocking device

Flush-mounted installation

Width in number of modular spacings

2

Ambient temperature during operating

-25 .. 40°C

Connectable conductor cross section multi-wired

35 .. 35mm²

Degree of protection (IP)

IP20

Pollution degree

2

Connectable conductor cross section solid-core

35 .. 35mm²