Technical specifications

Rated fault current0.3A
Surge current capacity0.25kA
Rated voltage230V
Voltage typeAC
Rated insulation voltage Ui500V
Current limiting class3
Leakage current typeAC
Release characteristicC
Rated current3.76A
Built-in depth72mm
Over voltage category3
Concurrently switching neutral conductorYes
Degree of protection (IP)IP20
Pollution degree2
Width in number of modular spacings2
Rated short-circuit breaking capacity according to IEC 60947-26kA
Number of protected poles1
Power loss20W
Frequency50/60 Hz
Number of poles (total)2
Connectable conductor cross section solid-core35 - 35mm²
Flush-mounted installationNo
Ambient temperature during operating-25 - 40°C
With interlocking deviceNo
Connectable conductor cross section multi-wired35 - 35mm²
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity Icn according to EN 61009-14.5kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity according to EN 610094.5kA
Anti-nuisance tripping versionNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW94018

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated fault current

0.3A

Surge current capacity

0.25kA

Rated voltage

230V

Voltage type

AC

Rated insulation voltage Ui

500V

Current limiting class

3

Leakage current type

AC

Release characteristic

C

Rated current

3.76A

Built-in depth

72mm

Over voltage category

3

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Pollution degree

2

Width in number of modular spacings

2

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Number of protected poles

1

Power loss

20W

Frequency

50/60 Hz

Number of poles (total)

2

Connectable conductor cross section solid-core

35 .. 35mm²

Flush-mounted installation

Ambient temperature during operating

-25 .. 40°C

With interlocking device

Connectable conductor cross section multi-wired

35 .. 35mm²

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity Icn according to EN 61009-1

4.5kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity according to EN 61009

4.5kA