Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)2
Rated voltage230V
Rated impulse withstand voltage Uimp4kV
Current limiting class3
Rated current6A
Power loss6W
Number of protected poles2
Rated short-circuit breaking capacity according to EN 610094.5kA
Rated fault current0.03A
Disconnection characteristicUndelayed
Rated insulation voltage Ui500V
Surge current capacity0.25kA
With interlocking deviceNo
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity according to IEC 60947-26kA
Leakage current typeAC
Frequency50/60 Hz
Width in number of modular spacings2
Flush-mounted installationNo
Anti-nuisance tripping versionNo
Degree of protection (IP)IP20
Connectable conductor cross section solid-core35 - 35mm²
Connectable conductor cross section multi-wired35 - 35mm²
Voltage typeAC
Release characteristicC
Rated short-circuit breaking capacity Icn according to EN 61009-14.5kA
Over voltage category3
Built-in depth72mm
Pollution degree2
Ambient temperature during operating-25 - 40°C
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW94025 | Compact RCBO 2P C6 4.5KA AC/0.03 2M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)

2

Rated voltage

230V

Rated impulse withstand voltage Uimp

4kV

Current limiting class

3

Rated current

6A

Power loss

6W

Number of protected poles

2

Rated short-circuit breaking capacity according to EN 61009

4.5kA

Rated fault current

0.03A

Disconnection characteristic

Undelayed

Rated insulation voltage Ui

500V

Surge current capacity

0.25kA

With interlocking device

Concurrently switching neutral conductor

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Leakage current type

AC

Frequency

50/60 Hz

Width in number of modular spacings

2

Flush-mounted installation

Anti-nuisance tripping version

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

35 .. 35mm²

Connectable conductor cross section multi-wired

35 .. 35mm²

Voltage type

AC

Release characteristic

C

Rated short-circuit breaking capacity Icn according to EN 61009-1

4.5kA

Over voltage category

3

Built-in depth

72mm

Pollution degree

2

Ambient temperature during operating

-25 .. 40°C

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.