Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth72mm
Current limiting class3
Rated fault current0.03A
Release characteristicC
Over voltage category3
Rated voltage230V
Voltage typeAC
Rated current13A
Surge current capacity0.25kA
Rated insulation voltage Ui500V
Leakage current typeAC
Number of protected poles2
Pollution degree2
Connectable conductor cross section solid-core35 - 35mm²
Ambient temperature during operating-25 - 40°C
Flush-mounted installationNo
Width in number of modular spacings2
Rated short-circuit breaking capacity according to IEC 60947-26kA
Concurrently switching neutral conductorNo
Frequency50/60 Hz
With interlocking deviceNo
Connectable conductor cross section multi-wired35 - 35mm²
Degree of protection (IP)IP20
Power loss13W
Disconnection characteristicUndelayed
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity according to EN 610094.5kA
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 61009-14.5kA
Anti-nuisance tripping versionNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW94031

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth

72mm

Current limiting class

3

Rated fault current

0.03A

Release characteristic

C

Over voltage category

3

Rated voltage

230V

Voltage type

AC

Rated current

13A

Surge current capacity

0.25kA

Rated insulation voltage Ui

500V

Leakage current type

AC

Number of protected poles

2

Pollution degree

2

Connectable conductor cross section solid-core

35 .. 35mm²

Ambient temperature during operating

-25 .. 40°C

Flush-mounted installation

Width in number of modular spacings

2

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Concurrently switching neutral conductor

Frequency

50/60 Hz

With interlocking device

Connectable conductor cross section multi-wired

35 .. 35mm²

Degree of protection (IP)

IP20

Power loss

13W

Disconnection characteristic

Undelayed

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity according to EN 61009

4.5kA

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 61009-1

4.5kA

Anti-nuisance tripping version