Technical specifications

Rated current2.12A
Built-in depth72mm
Voltage typeAC
Surge current capacity0.25kA
Pollution degree2
Width in number of modular spacings2
Current limiting class3
Rated fault current0.3A
Over voltage category3
Leakage current typeAC
Release characteristicC
Rated voltage230V
Rated insulation voltage Ui500V
Power loss6W
Ambient temperature during operating-25 - 40°C
Connectable conductor cross section multi-wired35 - 35mm²
Flush-mounted installationNo
Number of poles (total)2
Rated short-circuit breaking capacity according to IEC 60947-26kA
Anti-nuisance tripping versionNo
Degree of protection (IP)IP20
Number of protected poles2
Connectable conductor cross section solid-core35 - 35mm²
Rated short-circuit breaking capacity Icn according to EN 61009-14.5kA
Frequency50/60 Hz
Concurrently switching neutral conductorNo
Rated impulse withstand voltage Uimp4kV
With interlocking deviceNo
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity according to EN 610094.5kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW94035

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated current

2.12A

Built-in depth

72mm

Voltage type

AC

Surge current capacity

0.25kA

Pollution degree

2

Width in number of modular spacings

2

Current limiting class

3

Rated fault current

0.3A

Over voltage category

3

Leakage current type

AC

Release characteristic

C

Rated voltage

230V

Rated insulation voltage Ui

500V

Power loss

6W

Ambient temperature during operating

-25 .. 40°C

Connectable conductor cross section multi-wired

35 .. 35mm²

Flush-mounted installation

Number of poles (total)

2

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Anti-nuisance tripping version

Degree of protection (IP)

IP20

Number of protected poles

2

Connectable conductor cross section solid-core

35 .. 35mm²

Rated short-circuit breaking capacity Icn according to EN 61009-1

4.5kA

Frequency

50/60 Hz

Concurrently switching neutral conductor

Rated impulse withstand voltage Uimp

4kV

With interlocking device

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity according to EN 61009

4.5kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.