Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)2
Rated voltage230V
Number of protected poles2
Rated insulation voltage Ui500V
Rated impulse withstand voltage Uimp4kV
Rated current6A
Rated fault current0.3A
Current limiting class3
Leakage current typeAC
Power loss6W
Rated short-circuit breaking capacity according to EN 610094.5kA
Rated short-circuit breaking capacity according to IEC 60947-26kA
Rated short-circuit breaking capacity Icn according to EN 61009-14.5kA
Disconnection characteristicUndelayed
Voltage typeAC
Surge current capacity0.25kA
Frequency50/60 Hz
Release characteristicC
Concurrently switching neutral conductorNo
Flush-mounted installationNo
Degree of protection (IP)IP20
Width in number of modular spacings2
Pollution degree2
With interlocking deviceNo
Ambient temperature during operating-25 - 40°C
Over voltage category3
Built-in depth72mm
Anti-nuisance tripping versionNo
Connectable conductor cross section solid-core35 - 35mm²
Connectable conductor cross section multi-wired35 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW94035 | Compact RCBO 2P C6 4.5KA AC/0.3 2M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)

2

Rated voltage

230V

Number of protected poles

2

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

4kV

Rated current

6A

Rated fault current

0.3A

Current limiting class

3

Leakage current type

AC

Power loss

6W

Rated short-circuit breaking capacity according to EN 61009

4.5kA

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

4.5kA

Disconnection characteristic

Undelayed

Voltage type

AC

Surge current capacity

0.25kA

Frequency

50/60 Hz

Release characteristic

C

Concurrently switching neutral conductor

Flush-mounted installation

Degree of protection (IP)

IP20

Width in number of modular spacings

2

Pollution degree

2

With interlocking device

Ambient temperature during operating

-25 .. 40°C

Over voltage category

3

Built-in depth

72mm

Anti-nuisance tripping version

Connectable conductor cross section solid-core

35 .. 35mm²

Connectable conductor cross section multi-wired

35 .. 35mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.