Technical specifications

Rated current25A
Rated fault current0.3A
Current limiting class3
Leakage current typeAC
Rated insulation voltage Ui500V
Surge current capacity0.25kA
Built-in depth72mm
Over voltage category3
Rated voltage230V
Voltage typeAC
Release characteristicC
Pollution degree2
Concurrently switching neutral conductorNo
Anti-nuisance tripping versionNo
With interlocking deviceNo
Power loss25W
Width in number of modular spacings2
Number of protected poles2
Rated short-circuit breaking capacity Icn according to EN 61009-14.5kA
Number of poles (total)2
Flush-mounted installationNo
Ambient temperature during operating-25 - 40°C
Rated short-circuit breaking capacity according to IEC 60947-26kA
Frequency50/60 Hz
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity according to EN 610094.5kA
Connectable conductor cross section multi-wired35 - 35mm²
Disconnection characteristicUndelayed
Connectable conductor cross section solid-core35 - 35mm²
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW94039

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated current

25A

Rated fault current

0.3A

Current limiting class

3

Leakage current type

AC

Rated insulation voltage Ui

500V

Surge current capacity

0.25kA

Built-in depth

72mm

Over voltage category

3

Rated voltage

230V

Voltage type

AC

Release characteristic

C

Pollution degree

2

Concurrently switching neutral conductor

Anti-nuisance tripping version

With interlocking device

Power loss

25W

Width in number of modular spacings

2

Number of protected poles

2

Rated short-circuit breaking capacity Icn according to EN 61009-1

4.5kA

Number of poles (total)

2

Flush-mounted installation

Ambient temperature during operating

-25 .. 40°C

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Frequency

50/60 Hz

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity according to EN 61009

4.5kA

Connectable conductor cross section multi-wired

35 .. 35mm²

Disconnection characteristic

Undelayed

Connectable conductor cross section solid-core

35 .. 35mm²

Degree of protection (IP)

IP20

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.