Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth72mm
Over voltage category3
Rated current8.64A
Surge current capacity0.25kA
Leakage current typeAC
Rated voltage400V
Rated fault current0.03A
Release characteristicC
Current limiting class1
Voltage typeAC
Rated insulation voltage Ui500V
Power loss25W
Pollution degree2
Width in number of modular spacings3
Number of protected poles3
Frequency50/60 Hz
Rated short-circuit breaking capacity according to IEC 60947-24.5kA
Degree of protection (IP)IP20
Rated impulse withstand voltage Uimp4kV
With interlocking deviceNo
Flush-mounted installationNo
Rated short-circuit breaking capacity according to EN 610094.5kA
Concurrently switching neutral conductorNo
Anti-nuisance tripping versionNo
Number of poles (total)3
Rated short-circuit breaking capacity Icn according to EN 61009-14.5kA
Ambient temperature during operating-25 - 40°C
Connectable conductor cross section solid-core35 - 35mm²
Connectable conductor cross section multi-wired35 - 35mm²
Disconnection characteristicUndelayed
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW94049

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth

72mm

Over voltage category

3

Rated current

8.64A

Surge current capacity

0.25kA

Leakage current type

AC

Rated voltage

400V

Rated fault current

0.03A

Release characteristic

C

Current limiting class

1

Voltage type

AC

Rated insulation voltage Ui

500V

Power loss

25W

Pollution degree

2

Width in number of modular spacings

3

Number of protected poles

3

Frequency

50/60 Hz

Rated short-circuit breaking capacity according to IEC 60947-2

4.5kA

Degree of protection (IP)

IP20

Rated impulse withstand voltage Uimp

4kV

With interlocking device

Flush-mounted installation

Rated short-circuit breaking capacity according to EN 61009

4.5kA

Concurrently switching neutral conductor

Anti-nuisance tripping version

Number of poles (total)

3

Rated short-circuit breaking capacity Icn according to EN 61009-1

4.5kA

Ambient temperature during operating

-25 .. 40°C

Connectable conductor cross section solid-core

35 .. 35mm²

Connectable conductor cross section multi-wired

35 .. 35mm²

Disconnection characteristic

Undelayed