Aleta.hr
Main Product Image

GW94059

Code: 1965864

ManufacturerRAZNO
Catalog numberGW94059
Type
EAN code8011564465848

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of protected poles

3

Number of poles (total)

3

Rated insulation voltage Ui

500V

Rated current

25A

Voltage type

AC

Disconnection characteristic

Undelayed

Release characteristic

C

Rated short-circuit breaking capacity according to IEC 60947-2

4.5kA

Pollution degree

2

Rated impulse withstand voltage Uimp

4kV

Rated voltage

400V

Connectable conductor cross section solid-core

35 - 35mm²

Power loss

25W

Built-in depth

72mm

Leakage current type

AC

Surge current capacity

0.25kA

Rated fault current

0.3A

Rated short-circuit breaking capacity Icn according to EN 61009-1

4.5kA

Frequency

50/60 Hz

Current limiting class

1

Ambient temperature during operating

-25 - 40°C

Rated short-circuit breaking capacity according to EN 61009

4.5kA

With interlocking device

No

Flush-mounted installation

No

Concurrently switching neutral conductor

No

Over voltage category

3

Degree of protection (IP)

IP20

Width in number of modular spacings

3

Connectable conductor cross section multi-wired

35 - 35mm²

Anti-nuisance tripping version

No

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

GW94059

Main Product Image

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of protected poles

3

Number of poles (total)

3

Rated insulation voltage Ui

500V

Rated current

25A

Voltage type

AC

Disconnection characteristic

Undelayed

Release characteristic

C

Rated short-circuit breaking capacity according to IEC 60947-2

4.5kA

Pollution degree

2

Rated impulse withstand voltage Uimp

4kV

Rated voltage

400V

Connectable conductor cross section solid-core

35 .. 35mm²

Power loss

25W

Built-in depth

72mm

Leakage current type

AC

Surge current capacity

0.25kA

Rated fault current

0.3A

Rated short-circuit breaking capacity Icn according to EN 61009-1

4.5kA

Frequency

50/60 Hz

Current limiting class

1

Ambient temperature during operating

-25 .. 40°C

Rated short-circuit breaking capacity according to EN 61009

4.5kA

With interlocking device

Flush-mounted installation

Concurrently switching neutral conductor

Over voltage category

3

Degree of protection (IP)

IP20

Width in number of modular spacings

3

Connectable conductor cross section multi-wired

35 .. 35mm²

Anti-nuisance tripping version

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.