Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated voltage400V
Rated current4.24A
Voltage typeAC
Built-in depth72mm
Current limiting class1
Rated insulation voltage Ui500V
Width in number of modular spacings4
Leakage current typeAC
Pollution degree2
With interlocking deviceNo
Release characteristicC
Surge current capacity0.25kA
Number of protected poles4
Connectable conductor cross section multi-wired35 - 35mm²
Ambient temperature during operating-25 - 40°C
Concurrently switching neutral conductorNo
Rated fault current0.3A
Over voltage category3
Rated short-circuit breaking capacity according to IEC 60947-24.5kA
Connectable conductor cross section solid-core35 - 35mm²
Degree of protection (IP)IP20
Power loss6W
Frequency50/60 Hz
Rated short-circuit breaking capacity Icn according to EN 61009-14.5kA
Disconnection characteristicUndelayed
Flush-mounted installationNo
Number of poles (total)4
Anti-nuisance tripping versionNo
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity according to EN 610094.5kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW94075

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated voltage

400V

Rated current

4.24A

Voltage type

AC

Built-in depth

72mm

Current limiting class

1

Rated insulation voltage Ui

500V

Width in number of modular spacings

4

Leakage current type

AC

Pollution degree

2

With interlocking device

Release characteristic

C

Surge current capacity

0.25kA

Number of protected poles

4

Connectable conductor cross section multi-wired

35 .. 35mm²

Ambient temperature during operating

-25 .. 40°C

Concurrently switching neutral conductor

Rated fault current

0.3A

Over voltage category

3

Rated short-circuit breaking capacity according to IEC 60947-2

4.5kA

Connectable conductor cross section solid-core

35 .. 35mm²

Degree of protection (IP)

IP20

Power loss

6W

Frequency

50/60 Hz

Rated short-circuit breaking capacity Icn according to EN 61009-1

4.5kA

Disconnection characteristic

Undelayed

Flush-mounted installation

Number of poles (total)

4

Anti-nuisance tripping version

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity according to EN 61009

4.5kA