Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Voltage typeAC
Rated current8.24A
Built-in depth72mm
Release characteristicC
Rated insulation voltage Ui500V
Rated voltage400V
Current limiting class1
Over voltage category3
Power loss10W
Leakage current typeAC
Pollution degree2
Surge current capacity0.25kA
Rated fault current0.3A
Width in number of modular spacings4
Connectable conductor cross section multi-wired35 - 35mm²
Ambient temperature during operating-25 - 40°C
Rated short-circuit breaking capacity according to IEC 60947-24.5kA
Number of protected poles4
Frequency50/60 Hz
Connectable conductor cross section solid-core35 - 35mm²
Concurrently switching neutral conductorNo
Degree of protection (IP)IP20
With interlocking deviceNo
Rated impulse withstand voltage Uimp4kV
Anti-nuisance tripping versionNo
Rated short-circuit breaking capacity Icn according to EN 61009-14.5kA
Rated short-circuit breaking capacity according to EN 610094.5kA
Number of poles (total)4
Flush-mounted installationNo
Disconnection characteristicUndelayed
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW94076

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Voltage type

AC

Rated current

8.24A

Built-in depth

72mm

Release characteristic

C

Rated insulation voltage Ui

500V

Rated voltage

400V

Current limiting class

1

Over voltage category

3

Power loss

10W

Leakage current type

AC

Pollution degree

2

Surge current capacity

0.25kA

Rated fault current

0.3A

Width in number of modular spacings

4

Connectable conductor cross section multi-wired

35 .. 35mm²

Ambient temperature during operating

-25 .. 40°C

Rated short-circuit breaking capacity according to IEC 60947-2

4.5kA

Number of protected poles

4

Frequency

50/60 Hz

Connectable conductor cross section solid-core

35 .. 35mm²

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

With interlocking device

Rated impulse withstand voltage Uimp

4kV

Anti-nuisance tripping version

Rated short-circuit breaking capacity Icn according to EN 61009-1

4.5kA

Rated short-circuit breaking capacity according to EN 61009

4.5kA

Number of poles (total)

4

Flush-mounted installation

Disconnection characteristic

Undelayed

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.