Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated voltage400V
Surge current capacity0.25kA
Power loss32W
Degree of protection (IP)IP20
Width in number of modular spacings4
Rated insulation voltage Ui500V
Leakage current typeAC
Number of protected poles4
Pollution degree2
Over voltage category3
Release characteristicC
Connectable conductor cross section solid-core35 - 35mm²
Concurrently switching neutral conductorNo
Rated current14.68A
Rated short-circuit breaking capacity according to IEC 60947-24.5kA
Built-in depth72mm
Rated fault current0.3A
Frequency50/60 Hz
Voltage typeAC
Current limiting class1
Flush-mounted installationNo
Connectable conductor cross section multi-wired35 - 35mm²
With interlocking deviceNo
Ambient temperature during operating-25 - 40°C
Anti-nuisance tripping versionNo
Rated impulse withstand voltage Uimp4kV
Disconnection characteristicUndelayed
Number of poles (total)4
Rated short-circuit breaking capacity Icn according to EN 61009-14.5kA
Rated short-circuit breaking capacity according to EN 610094.5kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW94080

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated voltage

400V

Surge current capacity

0.25kA

Power loss

32W

Degree of protection (IP)

IP20

Width in number of modular spacings

4

Rated insulation voltage Ui

500V

Leakage current type

AC

Number of protected poles

4

Pollution degree

2

Over voltage category

3

Release characteristic

C

Connectable conductor cross section solid-core

35 .. 35mm²

Concurrently switching neutral conductor

Rated current

14.68A

Rated short-circuit breaking capacity according to IEC 60947-2

4.5kA

Built-in depth

72mm

Rated fault current

0.3A

Frequency

50/60 Hz

Voltage type

AC

Current limiting class

1

Flush-mounted installation

Connectable conductor cross section multi-wired

35 .. 35mm²

With interlocking device

Ambient temperature during operating

-25 .. 40°C

Anti-nuisance tripping version

Rated impulse withstand voltage Uimp

4kV

Disconnection characteristic

Undelayed

Number of poles (total)

4

Rated short-circuit breaking capacity Icn according to EN 61009-1

4.5kA

Rated short-circuit breaking capacity according to EN 61009

4.5kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.