Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)2
Number of protected poles1
Rated voltage230V
Rated impulse withstand voltage Uimp4kV
Rated current10A
Rated insulation voltage Ui500V
Rated fault current0.03A
Leakage current typeA
Current limiting class3
Rated short-circuit breaking capacity according to EN 610094.5kA
Power loss10W
Rated short-circuit breaking capacity according to IEC 60947-26kA
Voltage typeAC
Disconnection characteristicUndelayed
Surge current capacity0.25kA
Release characteristicC
Rated short-circuit breaking capacity Icn according to EN 61009-14.5kA
Pollution degree2
Frequency50/60 Hz
Ambient temperature during operating-25 - 40°C
Concurrently switching neutral conductorYes
Built-in depth72mm
With interlocking deviceNo
Over voltage category3
Flush-mounted installationNo
Anti-nuisance tripping versionNo
Degree of protection (IP)IP20
Width in number of modular spacings2
Connectable conductor cross section solid-core35 - 35mm²
Connectable conductor cross section multi-wired35 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW94206 | Compact RCBO 1P+N C10 4.5KA A/0.03 2M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)

2

Number of protected poles

1

Rated voltage

230V

Rated impulse withstand voltage Uimp

4kV

Rated current

10A

Rated insulation voltage Ui

500V

Rated fault current

0.03A

Leakage current type

A

Current limiting class

3

Rated short-circuit breaking capacity according to EN 61009

4.5kA

Power loss

10W

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Voltage type

AC

Disconnection characteristic

Undelayed

Surge current capacity

0.25kA

Release characteristic

C

Rated short-circuit breaking capacity Icn according to EN 61009-1

4.5kA

Pollution degree

2

Frequency

50/60 Hz

Ambient temperature during operating

-25 .. 40°C

Concurrently switching neutral conductor

Built-in depth

72mm

With interlocking device

Over voltage category

3

Flush-mounted installation

Anti-nuisance tripping version

Degree of protection (IP)

IP20

Width in number of modular spacings

2

Connectable conductor cross section solid-core

35 .. 35mm²

Connectable conductor cross section multi-wired

35 .. 35mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.