Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated current6.33A
Built-in depth72mm
Rated voltage230V
Rated fault current0.03A
Release characteristicC
Voltage typeAC
Leakage current typeA
Rated insulation voltage Ui500V
Current limiting class3
Surge current capacity0.25kA
Pollution degree2
Over voltage category3
Connectable conductor cross section solid-core35 - 35mm²
Flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 61009-14.5kA
Number of poles (total)2
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 40°C
Concurrently switching neutral conductorYes
Rated short-circuit breaking capacity according to IEC 60947-26kA
Anti-nuisance tripping versionNo
Connectable conductor cross section multi-wired35 - 35mm²
Rated impulse withstand voltage Uimp4kV
With interlocking deviceNo
Number of protected poles1
Power loss32W
Disconnection characteristicUndelayed
Width in number of modular spacings2
Rated short-circuit breaking capacity according to EN 610094.5kA
Frequency50/60 Hz
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW94210

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated current

6.33A

Built-in depth

72mm

Rated voltage

230V

Rated fault current

0.03A

Release characteristic

C

Voltage type

AC

Leakage current type

A

Rated insulation voltage Ui

500V

Current limiting class

3

Surge current capacity

0.25kA

Pollution degree

2

Over voltage category

3

Connectable conductor cross section solid-core

35 .. 35mm²

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 61009-1

4.5kA

Number of poles (total)

2

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 40°C

Concurrently switching neutral conductor

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Anti-nuisance tripping version

Connectable conductor cross section multi-wired

35 .. 35mm²

Rated impulse withstand voltage Uimp

4kV

With interlocking device

Number of protected poles

1

Power loss

32W

Disconnection characteristic

Undelayed

Width in number of modular spacings

2

Rated short-circuit breaking capacity according to EN 61009

4.5kA

Frequency

50/60 Hz

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.