Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)2
Number of protected poles1
Rated insulation voltage Ui500V
Rated voltage230V
Rated impulse withstand voltage Uimp4kV
Rated fault current0.03A
Rated current13A
Leakage current typeA
Frequency50/60 Hz
With interlocking deviceNo
Over voltage category3
Concurrently switching neutral conductorYes
Pollution degree2
Release characteristicC
Anti-nuisance tripping versionNo
Ambient temperature during operating-25 - 40°C
Built-in depth72mm
Degree of protection (IP)IP20
Flush-mounted installationNo
Connectable conductor cross section multi-wired35 - 35mm²
Width in number of modular spacings2
Power loss13W
Rated short-circuit breaking capacity according to EN 610094.5kA
Connectable conductor cross section solid-core35 - 35mm²
Current limiting class3
Rated short-circuit breaking capacity according to IEC 60947-26kA
Disconnection characteristicUndelayed
Surge current capacity0.25kA
Rated short-circuit breaking capacity Icn according to EN 61009-14.5kA
Voltage typeAC
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW94211 | Compact RCBO 1P+N C13 4.5KA A/0.03 2M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)

2

Number of protected poles

1

Rated insulation voltage Ui

500V

Rated voltage

230V

Rated impulse withstand voltage Uimp

4kV

Rated fault current

0.03A

Rated current

13A

Leakage current type

A

Frequency

50/60 Hz

With interlocking device

Over voltage category

3

Concurrently switching neutral conductor

Pollution degree

2

Release characteristic

C

Anti-nuisance tripping version

Ambient temperature during operating

-25 .. 40°C

Built-in depth

72mm

Degree of protection (IP)

IP20

Flush-mounted installation

Connectable conductor cross section multi-wired

35 .. 35mm²

Width in number of modular spacings

2

Power loss

13W

Rated short-circuit breaking capacity according to EN 61009

4.5kA

Connectable conductor cross section solid-core

35 .. 35mm²

Current limiting class

3

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Disconnection characteristic

Undelayed

Surge current capacity

0.25kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

4.5kA

Voltage type

AC