Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated voltage230V
Rated insulation voltage Ui500V
Rated current2.32A
Voltage typeAC
Built-in depth72mm
Width in number of modular spacings2
Current limiting class3
Rated fault current0.3A
Release characteristicC
Leakage current typeA
Surge current capacity0.25kA
Pollution degree2
Over voltage category3
Concurrently switching neutral conductorYes
Power loss10W
Frequency50/60 Hz
Rated short-circuit breaking capacity according to IEC 60947-26kA
Connectable conductor cross section solid-core35 - 35mm²
Number of protected poles1
Degree of protection (IP)IP20
Flush-mounted installationNo
Number of poles (total)2
Rated short-circuit breaking capacity according to EN 610094.5kA
With interlocking deviceNo
Connectable conductor cross section multi-wired35 - 35mm²
Ambient temperature during operating-25 - 40°C
Rated short-circuit breaking capacity Icn according to EN 61009-14.5kA
Rated impulse withstand voltage Uimp4kV
Anti-nuisance tripping versionNo
Disconnection characteristicUndelayed
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW94216

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated voltage

230V

Rated insulation voltage Ui

500V

Rated current

2.32A

Voltage type

AC

Built-in depth

72mm

Width in number of modular spacings

2

Current limiting class

3

Rated fault current

0.3A

Release characteristic

C

Leakage current type

A

Surge current capacity

0.25kA

Pollution degree

2

Over voltage category

3

Concurrently switching neutral conductor

Power loss

10W

Frequency

50/60 Hz

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Connectable conductor cross section solid-core

35 .. 35mm²

Number of protected poles

1

Degree of protection (IP)

IP20

Flush-mounted installation

Number of poles (total)

2

Rated short-circuit breaking capacity according to EN 61009

4.5kA

With interlocking device

Connectable conductor cross section multi-wired

35 .. 35mm²

Ambient temperature during operating

-25 .. 40°C

Rated short-circuit breaking capacity Icn according to EN 61009-1

4.5kA

Rated impulse withstand voltage Uimp

4kV

Anti-nuisance tripping version

Disconnection characteristic

Undelayed

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.