Technical specifications

Rated voltage230V
Voltage typeAC
Concurrently switching neutral conductorYes
Over voltage category3
Rated current4.88A
Built-in depth72mm
Current limiting class3
Power loss25W
Surge current capacity0.25kA
Frequency50/60 Hz
Release characteristicC
Degree of protection (IP)IP20
Number of protected poles1
Rated insulation voltage Ui500V
Width in number of modular spacings2
Leakage current typeA
Rated fault current0.3A
Pollution degree2
Ambient temperature during operating-25 - 40°C
Connectable conductor cross section solid-core35 - 35mm²
Connectable conductor cross section multi-wired35 - 35mm²
Rated short-circuit breaking capacity according to IEC 60947-26kA
With interlocking deviceNo
Rated short-circuit breaking capacity Icn according to EN 61009-14.5kA
Flush-mounted installationNo
Rated impulse withstand voltage Uimp4kV
Anti-nuisance tripping versionNo
Rated short-circuit breaking capacity according to EN 610094.5kA
Number of poles (total)2
Disconnection characteristicUndelayed
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW94219

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated voltage

230V

Voltage type

AC

Concurrently switching neutral conductor

Over voltage category

3

Rated current

4.88A

Built-in depth

72mm

Current limiting class

3

Power loss

25W

Surge current capacity

0.25kA

Frequency

50/60 Hz

Release characteristic

C

Degree of protection (IP)

IP20

Number of protected poles

1

Rated insulation voltage Ui

500V

Width in number of modular spacings

2

Leakage current type

A

Rated fault current

0.3A

Pollution degree

2

Ambient temperature during operating

-25 .. 40°C

Connectable conductor cross section solid-core

35 .. 35mm²

Connectable conductor cross section multi-wired

35 .. 35mm²

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

With interlocking device

Rated short-circuit breaking capacity Icn according to EN 61009-1

4.5kA

Flush-mounted installation

Rated impulse withstand voltage Uimp

4kV

Anti-nuisance tripping version

Rated short-circuit breaking capacity according to EN 61009

4.5kA

Number of poles (total)

2

Disconnection characteristic

Undelayed