Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth72mm
Voltage typeAC
Rated current4.9A
Rated voltage230V
Surge current capacity0.25kA
Rated fault current0.03A
Leakage current typeA
Current limiting class3
Rated insulation voltage Ui500V
Release characteristicC
Pollution degree2
Frequency50/60 Hz
Power loss13W
Over voltage category3
Width in number of modular spacings2
Degree of protection (IP)IP20
Number of protected poles2
Concurrently switching neutral conductorNo
With interlocking deviceNo
Ambient temperature during operating-25 - 40°C
Connectable conductor cross section solid-core35 - 35mm²
Rated short-circuit breaking capacity according to IEC 60947-26kA
Connectable conductor cross section multi-wired35 - 35mm²
Flush-mounted installationNo
Number of poles (total)2
Rated impulse withstand voltage Uimp4kV
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity Icn according to EN 61009-14.5kA
Rated short-circuit breaking capacity according to EN 610094.5kA
Anti-nuisance tripping versionNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW94231

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth

72mm

Voltage type

AC

Rated current

4.9A

Rated voltage

230V

Surge current capacity

0.25kA

Rated fault current

0.03A

Leakage current type

A

Current limiting class

3

Rated insulation voltage Ui

500V

Release characteristic

C

Pollution degree

2

Frequency

50/60 Hz

Power loss

13W

Over voltage category

3

Width in number of modular spacings

2

Degree of protection (IP)

IP20

Number of protected poles

2

Concurrently switching neutral conductor

With interlocking device

Ambient temperature during operating

-25 .. 40°C

Connectable conductor cross section solid-core

35 .. 35mm²

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Connectable conductor cross section multi-wired

35 .. 35mm²

Flush-mounted installation

Number of poles (total)

2

Rated impulse withstand voltage Uimp

4kV

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity Icn according to EN 61009-1

4.5kA

Rated short-circuit breaking capacity according to EN 61009

4.5kA

Anti-nuisance tripping version

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.