Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Voltage typeAC
Pollution degree2
Built-in depth72mm
Over voltage category3
Rated insulation voltage Ui500V
Current limiting class3
Rated current4.12A
Surge current capacity0.25kA
Rated voltage230V
Release characteristicC
Rated fault current0.3A
Leakage current typeA
Degree of protection (IP)IP20
Frequency50/60 Hz
Width in number of modular spacings2
Power loss10W
Number of protected poles2
Number of poles (total)2
Disconnection characteristicUndelayed
Connectable conductor cross section multi-wired35 - 35mm²
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity according to EN 610094.5kA
Rated short-circuit breaking capacity Icn according to EN 61009-14.5kA
With interlocking deviceNo
Ambient temperature during operating-25 - 40°C
Rated short-circuit breaking capacity according to IEC 60947-26kA
Concurrently switching neutral conductorNo
Flush-mounted installationNo
Anti-nuisance tripping versionNo
Connectable conductor cross section solid-core35 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW94236

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Voltage type

AC

Pollution degree

2

Built-in depth

72mm

Over voltage category

3

Rated insulation voltage Ui

500V

Current limiting class

3

Rated current

4.12A

Surge current capacity

0.25kA

Rated voltage

230V

Release characteristic

C

Rated fault current

0.3A

Leakage current type

A

Degree of protection (IP)

IP20

Frequency

50/60 Hz

Width in number of modular spacings

2

Power loss

10W

Number of protected poles

2

Number of poles (total)

2

Disconnection characteristic

Undelayed

Connectable conductor cross section multi-wired

35 .. 35mm²

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity according to EN 61009

4.5kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

4.5kA

With interlocking device

Ambient temperature during operating

-25 .. 40°C

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Concurrently switching neutral conductor

Flush-mounted installation

Anti-nuisance tripping version

Connectable conductor cross section solid-core

35 .. 35mm²