Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Concurrently switching neutral conductorNo
Surge current capacity0.25kA
Number of protected poles2
Over voltage category3
Rated insulation voltage Ui500V
Release characteristicC
Rated current16A
Frequency50/60 Hz
Voltage typeAC
Built-in depth72mm
Rated fault current0.3A
Current limiting class3
Leakage current typeA
Power loss16W
Width in number of modular spacings2
Degree of protection (IP)IP20
Rated voltage230V
Pollution degree2
Connectable conductor cross section multi-wired35 - 35mm²
With interlocking deviceNo
Connectable conductor cross section solid-core35 - 35mm²
Rated short-circuit breaking capacity according to IEC 60947-26kA
Ambient temperature during operating-25 - 40°C
Anti-nuisance tripping versionNo
Rated short-circuit breaking capacity Icn according to EN 61009-14.5kA
Number of poles (total)2
Flush-mounted installationNo
Disconnection characteristicUndelayed
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity according to EN 610094.5kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW94237

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Concurrently switching neutral conductor

Surge current capacity

0.25kA

Number of protected poles

2

Over voltage category

3

Rated insulation voltage Ui

500V

Release characteristic

C

Rated current

16A

Frequency

50/60 Hz

Voltage type

AC

Built-in depth

72mm

Rated fault current

0.3A

Current limiting class

3

Leakage current type

A

Power loss

16W

Width in number of modular spacings

2

Degree of protection (IP)

IP20

Rated voltage

230V

Pollution degree

2

Connectable conductor cross section multi-wired

35 .. 35mm²

With interlocking device

Connectable conductor cross section solid-core

35 .. 35mm²

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Ambient temperature during operating

-25 .. 40°C

Anti-nuisance tripping version

Rated short-circuit breaking capacity Icn according to EN 61009-1

4.5kA

Number of poles (total)

2

Flush-mounted installation

Disconnection characteristic

Undelayed

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity according to EN 61009

4.5kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.