Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Current limiting class1
Over voltage category3
Surge current capacity0.25kA
Built-in depth72mm
Rated current8.24A
Release characteristicC
Pollution degree2
Rated insulation voltage Ui500V
Rated fault current0.03A
Voltage typeAC
Rated voltage400V
Leakage current typeA
With interlocking deviceNo
Degree of protection (IP)IP20
Number of protected poles4
Power loss10W
Connectable conductor cross section solid-core35 - 35mm²
Frequency50/60 Hz
Rated short-circuit breaking capacity according to IEC 60947-24.5kA
Concurrently switching neutral conductorNo
Connectable conductor cross section multi-wired35 - 35mm²
Width in number of modular spacings4
Rated impulse withstand voltage Uimp4kV
Ambient temperature during operating-25 - 40°C
Rated short-circuit breaking capacity according to EN 610094.5kA
Number of poles (total)4
Rated short-circuit breaking capacity Icn according to EN 61009-14.5kA
Disconnection characteristicUndelayed
Anti-nuisance tripping versionNo
Flush-mounted installationNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW94266

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Current limiting class

1

Over voltage category

3

Surge current capacity

0.25kA

Built-in depth

72mm

Rated current

8.24A

Release characteristic

C

Pollution degree

2

Rated insulation voltage Ui

500V

Rated fault current

0.03A

Voltage type

AC

Rated voltage

400V

Leakage current type

A

With interlocking device

Degree of protection (IP)

IP20

Number of protected poles

4

Power loss

10W

Connectable conductor cross section solid-core

35 .. 35mm²

Frequency

50/60 Hz

Rated short-circuit breaking capacity according to IEC 60947-2

4.5kA

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

35 .. 35mm²

Width in number of modular spacings

4

Rated impulse withstand voltage Uimp

4kV

Ambient temperature during operating

-25 .. 40°C

Rated short-circuit breaking capacity according to EN 61009

4.5kA

Number of poles (total)

4

Rated short-circuit breaking capacity Icn according to EN 61009-1

4.5kA

Disconnection characteristic

Undelayed

Anti-nuisance tripping version

Flush-mounted installation

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.