Technical specifications

Release characteristicC
Voltage typeAC
Rated current9.12A
Rated fault current0.03A
Rated voltage400V
Rated insulation voltage Ui500V
Over voltage category3
Current limiting class1
Leakage current typeA
Degree of protection (IP)IP20
Built-in depth72mm
Width in number of modular spacings4
Surge current capacity0.25kA
Frequency50/60 Hz
Power loss16W
Pollution degree2
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity according to IEC 60947-24.5kA
Number of protected poles4
Ambient temperature during operating-25 - 40°C
Number of poles (total)4
Connectable conductor cross section solid-core35 - 35mm²
Anti-nuisance tripping versionNo
Rated impulse withstand voltage Uimp4kV
Connectable conductor cross section multi-wired35 - 35mm²
Concurrently switching neutral conductorNo
With interlocking deviceNo
Rated short-circuit breaking capacity according to EN 610094.5kA
Rated short-circuit breaking capacity Icn according to EN 61009-14.5kA
Flush-mounted installationNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW94267

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Release characteristic

C

Voltage type

AC

Rated current

9.12A

Rated fault current

0.03A

Rated voltage

400V

Rated insulation voltage Ui

500V

Over voltage category

3

Current limiting class

1

Leakage current type

A

Degree of protection (IP)

IP20

Built-in depth

72mm

Width in number of modular spacings

4

Surge current capacity

0.25kA

Frequency

50/60 Hz

Power loss

16W

Pollution degree

2

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity according to IEC 60947-2

4.5kA

Number of protected poles

4

Ambient temperature during operating

-25 .. 40°C

Number of poles (total)

4

Connectable conductor cross section solid-core

35 .. 35mm²

Anti-nuisance tripping version

Rated impulse withstand voltage Uimp

4kV

Connectable conductor cross section multi-wired

35 .. 35mm²

Concurrently switching neutral conductor

With interlocking device

Rated short-circuit breaking capacity according to EN 61009

4.5kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

4.5kA

Flush-mounted installation