Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)4
Number of protected poles4
Power loss20W
Surge current capacity0.25kA
Disconnection characteristicUndelayed
Current limiting class1
Frequency50/60 Hz
Rated short-circuit breaking capacity Icn according to EN 61009-14.5kA
Release characteristicC
Voltage typeAC
Pollution degree2
Width in number of modular spacings4
Over voltage category3
With interlocking deviceNo
Concurrently switching neutral conductorNo
Rated voltage400V
Rated insulation voltage Ui500V
Rated impulse withstand voltage Uimp4kV
Rated current20A
Rated fault current0.03A
Leakage current typeA
Rated short-circuit breaking capacity according to IEC 60947-24.5kA
Rated short-circuit breaking capacity according to EN 610094.5kA
Ambient temperature during operating-25 - 40°C
Degree of protection (IP)IP20
Built-in depth72mm
Connectable conductor cross section solid-core35 - 35mm²
Flush-mounted installationNo
Connectable conductor cross section multi-wired35 - 35mm²
Anti-nuisance tripping versionNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW94268 | Compact RCBO 4P C20 4.5KA A/0.03 4M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)

4

Number of protected poles

4

Power loss

20W

Surge current capacity

0.25kA

Disconnection characteristic

Undelayed

Current limiting class

1

Frequency

50/60 Hz

Rated short-circuit breaking capacity Icn according to EN 61009-1

4.5kA

Release characteristic

C

Voltage type

AC

Pollution degree

2

Width in number of modular spacings

4

Over voltage category

3

With interlocking device

Concurrently switching neutral conductor

Rated voltage

400V

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

4kV

Rated current

20A

Rated fault current

0.03A

Leakage current type

A

Rated short-circuit breaking capacity according to IEC 60947-2

4.5kA

Rated short-circuit breaking capacity according to EN 61009

4.5kA

Ambient temperature during operating

-25 .. 40°C

Degree of protection (IP)

IP20

Built-in depth

72mm

Connectable conductor cross section solid-core

35 .. 35mm²

Flush-mounted installation

Connectable conductor cross section multi-wired

35 .. 35mm²

Anti-nuisance tripping version

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.