Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Voltage typeAC
Rated voltage400V
Release characteristicC
Rated current8.24A
Built-in depth72mm
Current limiting class1
Surge current capacity0.25kA
Rated insulation voltage Ui500V
Over voltage category3
Leakage current typeA
Width in number of modular spacings4
Frequency50/60 Hz
Concurrently switching neutral conductorNo
Power loss10W
Pollution degree2
Degree of protection (IP)IP20
Number of protected poles4
Connectable conductor cross section solid-core35 - 35mm²
Connectable conductor cross section multi-wired35 - 35mm²
Rated short-circuit breaking capacity according to IEC 60947-24.5kA
Rated fault current0.3A
Number of poles (total)4
Flush-mounted installationNo
Anti-nuisance tripping versionNo
With interlocking deviceNo
Rated short-circuit breaking capacity Icn according to EN 61009-14.5kA
Disconnection characteristicUndelayed
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity according to EN 610094.5kA
Ambient temperature during operating-25 - 40°C
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW94276

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Voltage type

AC

Rated voltage

400V

Release characteristic

C

Rated current

8.24A

Built-in depth

72mm

Current limiting class

1

Surge current capacity

0.25kA

Rated insulation voltage Ui

500V

Over voltage category

3

Leakage current type

A

Width in number of modular spacings

4

Frequency

50/60 Hz

Concurrently switching neutral conductor

Power loss

10W

Pollution degree

2

Degree of protection (IP)

IP20

Number of protected poles

4

Connectable conductor cross section solid-core

35 .. 35mm²

Connectable conductor cross section multi-wired

35 .. 35mm²

Rated short-circuit breaking capacity according to IEC 60947-2

4.5kA

Rated fault current

0.3A

Number of poles (total)

4

Flush-mounted installation

Anti-nuisance tripping version

With interlocking device

Rated short-circuit breaking capacity Icn according to EN 61009-1

4.5kA

Disconnection characteristic

Undelayed

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity according to EN 61009

4.5kA

Ambient temperature during operating

-25 .. 40°C

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.