Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)2
Number of protected poles1
Power loss6W
Rated current6A
Rated impulse withstand voltage Uimp4kV
Rated insulation voltage Ui500V
Leakage current typeAC
Rated fault current0.03A
Current limiting class3
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity according to EN 610096kA
Rated short-circuit breaking capacity according to IEC 60947-210kA
Voltage typeAC
Surge current capacity0.25kA
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Frequency50/60 Hz
Over voltage category3
Anti-nuisance tripping versionNo
Rated voltage230V
Pollution degree2
Concurrently switching neutral conductorYes
Ambient temperature during operating-25 - 40°C
Release characteristicC
Degree of protection (IP)IP20
With interlocking deviceNo
Built-in depth72mm
Flush-mounted installationNo
Width in number of modular spacings2
Connectable conductor cross section multi-wired35 - 35mm²
Connectable conductor cross section solid-core35 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW94105 | Compact RCBO 1P+N C6 6KA AC/0.03 2M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)

2

Number of protected poles

1

Power loss

6W

Rated current

6A

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

500V

Leakage current type

AC

Rated fault current

0.03A

Current limiting class

3

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity according to EN 61009

6kA

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Voltage type

AC

Surge current capacity

0.25kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Frequency

50/60 Hz

Over voltage category

3

Anti-nuisance tripping version

Rated voltage

230V

Pollution degree

2

Concurrently switching neutral conductor

Ambient temperature during operating

-25 .. 40°C

Release characteristic

C

Degree of protection (IP)

IP20

With interlocking device

Built-in depth

72mm

Flush-mounted installation

Width in number of modular spacings

2

Connectable conductor cross section multi-wired

35 .. 35mm²

Connectable conductor cross section solid-core

35 .. 35mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.