Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)2
Rated voltage230V
Number of protected poles1
Rated impulse withstand voltage Uimp4kV
Rated insulation voltage Ui500V
Rated current32A
Rated fault current0.03A
Leakage current typeAC
Current limiting class3
Rated short-circuit breaking capacity according to IEC 60947-210kA
Power loss32W
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Rated short-circuit breaking capacity according to EN 610096kA
Disconnection characteristicUndelayed
Pollution degree2
Built-in depth72mm
Surge current capacity0.25kA
Voltage typeAC
Frequency50/60 Hz
Release characteristicC
Concurrently switching neutral conductorYes
With interlocking deviceNo
Over voltage category3
Flush-mounted installationNo
Ambient temperature during operating-25 - 40°C
Width in number of modular spacings2
Degree of protection (IP)IP20
Connectable conductor cross section solid-core35 - 35mm²
Connectable conductor cross section multi-wired35 - 35mm²
Anti-nuisance tripping versionNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW94110 | Compact RCBO 1P+N C32 6KA AC/0.03 2M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)

2

Rated voltage

230V

Number of protected poles

1

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

500V

Rated current

32A

Rated fault current

0.03A

Leakage current type

AC

Current limiting class

3

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Power loss

32W

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Rated short-circuit breaking capacity according to EN 61009

6kA

Disconnection characteristic

Undelayed

Pollution degree

2

Built-in depth

72mm

Surge current capacity

0.25kA

Voltage type

AC

Frequency

50/60 Hz

Release characteristic

C

Concurrently switching neutral conductor

With interlocking device

Over voltage category

3

Flush-mounted installation

Ambient temperature during operating

-25 .. 40°C

Width in number of modular spacings

2

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

35 .. 35mm²

Connectable conductor cross section multi-wired

35 .. 35mm²

Anti-nuisance tripping version