Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)2
Number of protected poles1
Rated voltage230V
Rated insulation voltage Ui500V
Rated impulse withstand voltage Uimp4kV
Rated fault current0.03A
Rated current13A
Leakage current typeAC
Current limiting class3
Power loss13W
Rated short-circuit breaking capacity according to IEC 60947-210kA
Rated short-circuit breaking capacity according to EN 610096kA
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Disconnection characteristicUndelayed
Surge current capacity0.25kA
Voltage typeAC
Frequency50/60 Hz
Release characteristicC
Concurrently switching neutral conductorYes
With interlocking deviceNo
Over voltage category3
Pollution degree2
Ambient temperature during operating-25 - 40°C
Width in number of modular spacings2
Built-in depth72mm
Flush-mounted installationNo
Degree of protection (IP)IP20
Anti-nuisance tripping versionNo
Connectable conductor cross section solid-core35 - 35mm²
Connectable conductor cross section multi-wired35 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW94111 | Compact RCBO 1P+N C13 6KA AC/0.03 2M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)

2

Number of protected poles

1

Rated voltage

230V

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

4kV

Rated fault current

0.03A

Rated current

13A

Leakage current type

AC

Current limiting class

3

Power loss

13W

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Rated short-circuit breaking capacity according to EN 61009

6kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Disconnection characteristic

Undelayed

Surge current capacity

0.25kA

Voltage type

AC

Frequency

50/60 Hz

Release characteristic

C

Concurrently switching neutral conductor

With interlocking device

Over voltage category

3

Pollution degree

2

Ambient temperature during operating

-25 .. 40°C

Width in number of modular spacings

2

Built-in depth

72mm

Flush-mounted installation

Degree of protection (IP)

IP20

Anti-nuisance tripping version

Connectable conductor cross section solid-core

35 .. 35mm²

Connectable conductor cross section multi-wired

35 .. 35mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.