Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)2
Number of protected poles1
Rated voltage230V
Rated insulation voltage Ui500V
Rated impulse withstand voltage Uimp4kV
Rated current16A
Rated fault current0.3A
Leakage current typeAC
Current limiting class3
Power loss16W
Rated short-circuit breaking capacity according to EN 610096kA
Rated short-circuit breaking capacity according to IEC 60947-210kA
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Voltage typeAC
Disconnection characteristicUndelayed
Surge current capacity0.25kA
Release characteristicC
Frequency50/60 Hz
Concurrently switching neutral conductorYes
Pollution degree2
Width in number of modular spacings2
Ambient temperature during operating-25 - 40°C
With interlocking deviceNo
Over voltage category3
Built-in depth72mm
Flush-mounted installationNo
Anti-nuisance tripping versionNo
Degree of protection (IP)IP20
Connectable conductor cross section solid-core35 - 35mm²
Connectable conductor cross section multi-wired35 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW94117 | Compact RCBO 1P+N C16 6KA AC/0.3 2M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)

2

Number of protected poles

1

Rated voltage

230V

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

4kV

Rated current

16A

Rated fault current

0.3A

Leakage current type

AC

Current limiting class

3

Power loss

16W

Rated short-circuit breaking capacity according to EN 61009

6kA

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Voltage type

AC

Disconnection characteristic

Undelayed

Surge current capacity

0.25kA

Release characteristic

C

Frequency

50/60 Hz

Concurrently switching neutral conductor

Pollution degree

2

Width in number of modular spacings

2

Ambient temperature during operating

-25 .. 40°C

With interlocking device

Over voltage category

3

Built-in depth

72mm

Flush-mounted installation

Anti-nuisance tripping version

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

35 .. 35mm²

Connectable conductor cross section multi-wired

35 .. 35mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.