Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Surge current capacity0.25kA
Frequency50/60 Hz
Built-in depth72mm
Leakage current typeAC
Release characteristicC
Rated voltage230V
Degree of protection (IP)IP20
Pollution degree2
Current limiting class3
Over voltage category3
Width in number of modular spacings2
Power loss32W
Voltage typeAC
Rated insulation voltage Ui500V
Rated fault current0.3A
Rated short-circuit breaking capacity according to IEC 60947-210kA
Number of protected poles1
Concurrently switching neutral conductorYes
Rated current32A
Rated impulse withstand voltage Uimp4kV
Ambient temperature during operating-25 - 40°C
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
With interlocking deviceNo
Number of poles (total)2
Disconnection characteristicUndelayed
Flush-mounted installationNo
Connectable conductor cross section solid-core35 - 35mm²
Anti-nuisance tripping versionNo
Rated short-circuit breaking capacity according to EN 610096kA
Connectable conductor cross section multi-wired35 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW94120

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Surge current capacity

0.25kA

Frequency

50/60 Hz

Built-in depth

72mm

Leakage current type

AC

Release characteristic

C

Rated voltage

230V

Degree of protection (IP)

IP20

Pollution degree

2

Current limiting class

3

Over voltage category

3

Width in number of modular spacings

2

Power loss

32W

Voltage type

AC

Rated insulation voltage Ui

500V

Rated fault current

0.3A

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Number of protected poles

1

Concurrently switching neutral conductor

Rated current

32A

Rated impulse withstand voltage Uimp

4kV

Ambient temperature during operating

-25 .. 40°C

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

With interlocking device

Number of poles (total)

2

Disconnection characteristic

Undelayed

Flush-mounted installation

Connectable conductor cross section solid-core

35 .. 35mm²

Anti-nuisance tripping version

Rated short-circuit breaking capacity according to EN 61009

6kA

Connectable conductor cross section multi-wired

35 .. 35mm²