Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Voltage typeAC
Rated voltage230V
Rated current2.12A
Built-in depth72mm
Rated insulation voltage Ui500V
Rated fault current0.03A
Release characteristicC
Leakage current typeAC
Surge current capacity0.25kA
Current limiting class3
Pollution degree2
Over voltage category3
Width in number of modular spacings2
Degree of protection (IP)IP20
Frequency50/60 Hz
Power loss6W
Rated short-circuit breaking capacity according to IEC 60947-210kA
Connectable conductor cross section solid-core35 - 35mm²
With interlocking deviceNo
Connectable conductor cross section multi-wired35 - 35mm²
Number of protected poles2
Concurrently switching neutral conductorNo
Disconnection characteristicUndelayed
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Number of poles (total)2
Anti-nuisance tripping versionNo
Rated short-circuit breaking capacity according to EN 610096kA
Flush-mounted installationNo
Ambient temperature during operating-25 - 40°C
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW94125

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Voltage type

AC

Rated voltage

230V

Rated current

2.12A

Built-in depth

72mm

Rated insulation voltage Ui

500V

Rated fault current

0.03A

Release characteristic

C

Leakage current type

AC

Surge current capacity

0.25kA

Current limiting class

3

Pollution degree

2

Over voltage category

3

Width in number of modular spacings

2

Degree of protection (IP)

IP20

Frequency

50/60 Hz

Power loss

6W

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Connectable conductor cross section solid-core

35 .. 35mm²

With interlocking device

Connectable conductor cross section multi-wired

35 .. 35mm²

Number of protected poles

2

Concurrently switching neutral conductor

Disconnection characteristic

Undelayed

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Number of poles (total)

2

Anti-nuisance tripping version

Rated short-circuit breaking capacity according to EN 61009

6kA

Flush-mounted installation

Ambient temperature during operating

-25 .. 40°C

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.