Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Frequency50/60 Hz
Leakage current typeAC
Over voltage category3
Rated fault current0.03A
Surge current capacity0.25kA
Rated insulation voltage Ui500V
Voltage typeAC
Degree of protection (IP)IP20
Rated voltage230V
Release characteristicC
Number of protected poles2
Power loss16W
Width in number of modular spacings2
Current limiting class3
Built-in depth72mm
Rated current4.56A
Pollution degree2
Flush-mounted installationNo
With interlocking deviceNo
Ambient temperature during operating-25 - 40°C
Concurrently switching neutral conductorNo
Connectable conductor cross section solid-core35 - 35mm²
Connectable conductor cross section multi-wired35 - 35mm²
Number of poles (total)2
Rated short-circuit breaking capacity according to IEC 60947-210kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Disconnection characteristicUndelayed
Anti-nuisance tripping versionNo
Rated short-circuit breaking capacity according to EN 610096kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW94127

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Frequency

50/60 Hz

Leakage current type

AC

Over voltage category

3

Rated fault current

0.03A

Surge current capacity

0.25kA

Rated insulation voltage Ui

500V

Voltage type

AC

Degree of protection (IP)

IP20

Rated voltage

230V

Release characteristic

C

Number of protected poles

2

Power loss

16W

Width in number of modular spacings

2

Current limiting class

3

Built-in depth

72mm

Rated current

4.56A

Pollution degree

2

Flush-mounted installation

With interlocking device

Ambient temperature during operating

-25 .. 40°C

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

35 .. 35mm²

Connectable conductor cross section multi-wired

35 .. 35mm²

Number of poles (total)

2

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Disconnection characteristic

Undelayed

Anti-nuisance tripping version

Rated short-circuit breaking capacity according to EN 61009

6kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.