Number of poles (total)2
Rated impulse withstand voltage Uimp4kV
Rated voltage230V
Number of protected poles2
Rated fault current0.03A
Rated insulation voltage Ui500V
Rated current16A
Current limiting class3
Leakage current typeAC
Power loss16W
Rated short-circuit breaking capacity according to IEC 60947-210kA
Surge current capacity0.25kA
Over voltage category3
Release characteristicC
Voltage typeAC
Width in number of modular spacings2
With interlocking deviceNo
Built-in depth72mm
Disconnection characteristicUndelayed
Frequency50/60 Hz
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Connectable conductor cross section solid-core35 - 35mm²
Flush-mounted installationNo
Concurrently switching neutral conductorNo
Ambient temperature during operating-25 - 40°C
Degree of protection (IP)IP20
Anti-nuisance tripping versionNo
Connectable conductor cross section multi-wired35 - 35mm²
Pollution degree2
Rated short-circuit breaking capacity according to EN 610096kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW94127 | Compact RCBO 2P C16 6KA AC/0.03 2M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)

2

Rated impulse withstand voltage Uimp

4kV

Rated voltage

230V

Number of protected poles

2

Rated fault current

0.03A

Rated insulation voltage Ui

500V

Rated current

16A

Current limiting class

3

Leakage current type

AC

Power loss

16W

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Surge current capacity

0.25kA

Over voltage category

3

Release characteristic

C

Voltage type

AC

Width in number of modular spacings

2

With interlocking device

Built-in depth

72mm

Disconnection characteristic

Undelayed

Frequency

50/60 Hz

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Connectable conductor cross section solid-core

35 .. 35mm²

Flush-mounted installation

Concurrently switching neutral conductor

Ambient temperature during operating

-25 .. 40°C

Degree of protection (IP)

IP20

Anti-nuisance tripping version

Connectable conductor cross section multi-wired

35 .. 35mm²

Pollution degree

2

Rated short-circuit breaking capacity according to EN 61009

6kA