Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Voltage typeAC
Built-in depth72mm
Rated voltage230V
Release characteristicC
Rated current20A
Over voltage category3
Rated fault current0.03A
Surge current capacity0.25kA
Power loss20W
Frequency50/60 Hz
Width in number of modular spacings2
Connectable conductor cross section multi-wired35 - 35mm²
Connectable conductor cross section solid-core35 - 35mm²
Pollution degree2
Number of poles (total)2
Concurrently switching neutral conductorNo
Rated impulse withstand voltage Uimp4kV
Flush-mounted installationNo
Ambient temperature during operating-25 - 40°C
Degree of protection (IP)IP20
Disconnection characteristicUndelayed
Number of protected poles2
Anti-nuisance tripping versionNo
Current limiting class3
Leakage current typeAC
Rated insulation voltage Ui500V
Rated short-circuit breaking capacity according to EN 610096kA
With interlocking deviceNo
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Rated short-circuit breaking capacity according to IEC 60947-210kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW94128

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Voltage type

AC

Built-in depth

72mm

Rated voltage

230V

Release characteristic

C

Rated current

20A

Over voltage category

3

Rated fault current

0.03A

Surge current capacity

0.25kA

Power loss

20W

Frequency

50/60 Hz

Width in number of modular spacings

2

Connectable conductor cross section multi-wired

35 .. 35mm²

Connectable conductor cross section solid-core

35 .. 35mm²

Pollution degree

2

Number of poles (total)

2

Concurrently switching neutral conductor

Rated impulse withstand voltage Uimp

4kV

Flush-mounted installation

Ambient temperature during operating

-25 .. 40°C

Degree of protection (IP)

IP20

Disconnection characteristic

Undelayed

Number of protected poles

2

Anti-nuisance tripping version

Current limiting class

3

Leakage current type

AC

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity according to EN 61009

6kA

With interlocking device

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.