Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth72mm
Voltage typeAC
Rated current13A
Rated voltage230V
Power loss13W
Current limiting class3
Surge current capacity0.25kA
Leakage current typeAC
Width in number of modular spacings2
Concurrently switching neutral conductorNo
Degree of protection (IP)IP20
Release characteristicC
Connectable conductor cross section solid-core35 - 35mm²
Connectable conductor cross section multi-wired35 - 35mm²
Anti-nuisance tripping versionNo
Ambient temperature during operating-25 - 40°C
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Rated insulation voltage Ui500V
Frequency50/60 Hz
Rated short-circuit breaking capacity according to IEC 60947-210kA
Over voltage category3
Pollution degree2
With interlocking deviceNo
Number of poles (total)2
Disconnection characteristicUndelayed
Number of protected poles2
Rated impulse withstand voltage Uimp4kV
Rated fault current0.03A
Flush-mounted installationNo
Rated short-circuit breaking capacity according to EN 610096kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW94131

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth

72mm

Voltage type

AC

Rated current

13A

Rated voltage

230V

Power loss

13W

Current limiting class

3

Surge current capacity

0.25kA

Leakage current type

AC

Width in number of modular spacings

2

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Release characteristic

C

Connectable conductor cross section solid-core

35 .. 35mm²

Connectable conductor cross section multi-wired

35 .. 35mm²

Anti-nuisance tripping version

Ambient temperature during operating

-25 .. 40°C

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Rated insulation voltage Ui

500V

Frequency

50/60 Hz

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Over voltage category

3

Pollution degree

2

With interlocking device

Number of poles (total)

2

Disconnection characteristic

Undelayed

Number of protected poles

2

Rated impulse withstand voltage Uimp

4kV

Rated fault current

0.03A

Flush-mounted installation

Rated short-circuit breaking capacity according to EN 61009

6kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.