Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)2
Number of protected poles2
Rated voltage230V
Rated impulse withstand voltage Uimp4kV
Rated insulation voltage Ui500V
Rated current6A
Rated fault current0.3A
Leakage current typeAC
Current limiting class3
Rated short-circuit breaking capacity according to EN 610096kA
Power loss6W
Rated short-circuit breaking capacity according to IEC 60947-210kA
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Disconnection characteristicUndelayed
With interlocking deviceNo
Concurrently switching neutral conductorNo
Over voltage category3
Ambient temperature during operating-25 - 40°C
Voltage typeAC
Surge current capacity0.25kA
Width in number of modular spacings2
Release characteristicC
Frequency50/60 Hz
Degree of protection (IP)IP20
Pollution degree2
Flush-mounted installationNo
Connectable conductor cross section solid-core35 - 35mm²
Anti-nuisance tripping versionNo
Built-in depth72mm
Connectable conductor cross section multi-wired35 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW94135 | Compact RCBO 2P C6 6KA AC/0.3 2M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)

2

Number of protected poles

2

Rated voltage

230V

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

500V

Rated current

6A

Rated fault current

0.3A

Leakage current type

AC

Current limiting class

3

Rated short-circuit breaking capacity according to EN 61009

6kA

Power loss

6W

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Disconnection characteristic

Undelayed

With interlocking device

Concurrently switching neutral conductor

Over voltage category

3

Ambient temperature during operating

-25 .. 40°C

Voltage type

AC

Surge current capacity

0.25kA

Width in number of modular spacings

2

Release characteristic

C

Frequency

50/60 Hz

Degree of protection (IP)

IP20

Pollution degree

2

Flush-mounted installation

Connectable conductor cross section solid-core

35 .. 35mm²

Anti-nuisance tripping version

Built-in depth

72mm

Connectable conductor cross section multi-wired

35 .. 35mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.