Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)2
Number of protected poles2
Rated insulation voltage Ui500V
Rated impulse withstand voltage Uimp4kV
Rated fault current0.3A
Rated current20A
Leakage current typeAC
Current limiting class3
Power loss20W
Rated short-circuit breaking capacity according to EN 610096kA
Frequency50/60 Hz
Release characteristicC
With interlocking deviceNo
Concurrently switching neutral conductorNo
Ambient temperature during operating-25 - 40°C
Flush-mounted installationNo
Pollution degree2
Anti-nuisance tripping versionNo
Degree of protection (IP)IP20
Built-in depth72mm
Rated voltage230V
Rated short-circuit breaking capacity according to IEC 60947-210kA
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Disconnection characteristicUndelayed
Surge current capacity0.25kA
Voltage typeAC
Width in number of modular spacings2
Connectable conductor cross section solid-core35 - 35mm²
Connectable conductor cross section multi-wired35 - 35mm²
Over voltage category3
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW94138 | Compact RCBO 2P C20 6KA AC/0.3 2M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)

2

Number of protected poles

2

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

4kV

Rated fault current

0.3A

Rated current

20A

Leakage current type

AC

Current limiting class

3

Power loss

20W

Rated short-circuit breaking capacity according to EN 61009

6kA

Frequency

50/60 Hz

Release characteristic

C

With interlocking device

Concurrently switching neutral conductor

Ambient temperature during operating

-25 .. 40°C

Flush-mounted installation

Pollution degree

2

Anti-nuisance tripping version

Degree of protection (IP)

IP20

Built-in depth

72mm

Rated voltage

230V

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Disconnection characteristic

Undelayed

Surge current capacity

0.25kA

Voltage type

AC

Width in number of modular spacings

2

Connectable conductor cross section solid-core

35 .. 35mm²

Connectable conductor cross section multi-wired

35 .. 35mm²

Over voltage category

3