Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Release characteristicC
Built-in depth72mm
Rated voltage400V
Rated insulation voltage Ui500V
Leakage current typeAC
Voltage typeAC
Rated fault current0.03A
Current limiting class1
Surge current capacity0.25kA
Rated current8.64A
Over voltage category3
Pollution degree2
Power loss25W
Degree of protection (IP)IP20
Frequency50/60 Hz
Width in number of modular spacings3
Number of protected poles3
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity according to IEC 60947-26kA
Connectable conductor cross section solid-core35 - 35mm²
Connectable conductor cross section multi-wired35 - 35mm²
With interlocking deviceNo
Anti-nuisance tripping versionNo
Disconnection characteristicUndelayed
Number of poles (total)3
Rated short-circuit breaking capacity according to EN 610096kA
Flush-mounted installationNo
Ambient temperature during operating-25 - 40°C
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW94149

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Release characteristic

C

Built-in depth

72mm

Rated voltage

400V

Rated insulation voltage Ui

500V

Leakage current type

AC

Voltage type

AC

Rated fault current

0.03A

Current limiting class

1

Surge current capacity

0.25kA

Rated current

8.64A

Over voltage category

3

Pollution degree

2

Power loss

25W

Degree of protection (IP)

IP20

Frequency

50/60 Hz

Width in number of modular spacings

3

Number of protected poles

3

Concurrently switching neutral conductor

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Connectable conductor cross section solid-core

35 .. 35mm²

Connectable conductor cross section multi-wired

35 .. 35mm²

With interlocking device

Anti-nuisance tripping version

Disconnection characteristic

Undelayed

Number of poles (total)

3

Rated short-circuit breaking capacity according to EN 61009

6kA

Flush-mounted installation

Ambient temperature during operating

-25 .. 40°C

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA