Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated fault current0.03A
Rated current7.47A
Pollution degree2
Surge current capacity0.25kA
Voltage typeAC
Leakage current typeAC
Release characteristicC
Rated insulation voltage Ui500V
Degree of protection (IP)IP20
Over voltage category3
Power loss13W
Frequency50/60 Hz
Width in number of modular spacings3
Current limiting class1
Built-in depth72mm
Rated voltage400V
Concurrently switching neutral conductorNo
Number of protected poles3
Connectable conductor cross section solid-core35 - 35mm²
Rated short-circuit breaking capacity according to IEC 60947-26kA
Connectable conductor cross section multi-wired35 - 35mm²
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Anti-nuisance tripping versionNo
Rated impulse withstand voltage Uimp4kV
With interlocking deviceNo
Rated short-circuit breaking capacity according to EN 610096kA
Disconnection characteristicUndelayed
Ambient temperature during operating-25 - 40°C
Number of poles (total)3
Flush-mounted installationNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW94151

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated fault current

0.03A

Rated current

7.47A

Pollution degree

2

Surge current capacity

0.25kA

Voltage type

AC

Leakage current type

AC

Release characteristic

C

Rated insulation voltage Ui

500V

Degree of protection (IP)

IP20

Over voltage category

3

Power loss

13W

Frequency

50/60 Hz

Width in number of modular spacings

3

Current limiting class

1

Built-in depth

72mm

Rated voltage

400V

Concurrently switching neutral conductor

Number of protected poles

3

Connectable conductor cross section solid-core

35 .. 35mm²

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Connectable conductor cross section multi-wired

35 .. 35mm²

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Anti-nuisance tripping version

Rated impulse withstand voltage Uimp

4kV

With interlocking device

Rated short-circuit breaking capacity according to EN 61009

6kA

Disconnection characteristic

Undelayed

Ambient temperature during operating

-25 .. 40°C

Number of poles (total)

3

Flush-mounted installation

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.